Rugged 16-gauge zinc coated G-90 steel, with electro-deposition finish resists corrosion and fading
NEMA 3R rainproof enclosure protects against weather, vandalism and nuisance tripping
Factory wired, assembled and tested
All-in-1 construction for factory assured terminations
Description
Unmetered RV outlet box. Rugged 16-gauge zinc coated G-90 steel, with electro-deposition finish resists corrosion and fading. NEMA 3R rainproof enclosure protects against weather, vandalism and nuisance tripping. Factory wired, assembled and tested. All-in-1 construction for factory assured terminations. Suitable for use as service entrance equipment when installed in accordance with the National Electric Code. Accepts copper or aluminum wire for added installation flexibility. Rolled edge door for cord protection. Dead front construction prevents accidental contact with live parts. Stay open position on door for convenience. Padlock provision. UL/CUL Listed (Power Outlets).
Double pole, 50 Amp, type QPF2 GFCI Circuit Breaker
10,000 AIC interrupting rating
Includes self-test as required by UL 943 as an added safety feature
Suitable for a variety of construction applications including spas, hot tubs, kitchens, bathrooms, etc.
Provides class A GFCI protection
Description
Testing GFCIs and afcis on a monthly basis is a good idea that is sometimes forgotten. Underwriters laboratories (UL) suggests that afci/GFCI Devices be tested every 30 days after installation to ensure they are properly working. Now the new self test & lockout feature enables the dual function circuit breaker to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly assuming that the device was tripped to prevent a ground/arc fault. This effortless system guarantees that only the best protection is given to your home at all times.
3. Siemens MC0816B1200RCT Speed fax Load Center, 120/240 Vac, 200 A, Mbk200 Main Breaker
For use in Siemens panels that accept type QT circuit breakers
Quad breakers provide two sets of common trip 2-pole breakers
Requires 2-panel spaces
Description
Product Description
Siemens space saving, plug in circuit breakers are intended for use in Siemens EQ, Siemens Ultimate, ITE, and Gould load centers and meter combinations that are rated to accept type QT breakers. Check wiring diagram to confirm. To ensure the warranty on a Siemens panel is not voided, the use of Siemens breakers is required. The quadplex breakers provide two double pole breakers in half the space of standard sized breakers. These triplex, 1/2-Inch frame breakers are ideal when new circuits are required in a panel that has no available spaces. Siemens strongly recommends against the use of “used” breakers. The installation of used breakers in a Siemens panel will void the warranty on the panel. Siemens does not sell used breakers and has not approved any 3rd party sellers to do so.
From the Manufacturer
SIEMENS space saving, plug in circuit breakers are intended for use in SIEMENS EQ, SIEMENS Ultimate, ITE, and Gould load centers and meter combinations that are rated to accept type QT breakers. Check wiring diagram to confirm. To ensure the warranty on a SIEMENS panel is not voided, the use of SIEMENS breakers is required. The quadplex breakers provide two double pole breakers in half the space of standard sized breakers. These triplex, 1/2-Inch frame breakers are ideal when new circuits are required in a panel that has no available spaces.
6. Q250 50-Amp Double Pole Type QP Circuit Breaker
Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
Compatible with Siemens PL and ES series load centers
Use for overload and short-circuit protection of your electrical system
Description
Product Description
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home’s electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home’s wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current. To ensure the warranty on a Siemens panel is not voided, the use of Siemens breakers is required. Siemens strongly recommends against the use of “used” breakers. The installation of used breakers in a Siemens panel will void the warranty on the panel. Siemens does not sell used breakers and has not approved any 3rd party sellers to do so.
From the Manufacturer
Siemens plug in circuit breakers are intended for use in Siemens EQ, Siemens Ultimate, ITE, and Gould load centers or meter combinations. The double pole Siemens breakers may be used in 1 or 3-phase load centers and are 240V rated. To ensure the warranty on a Siemens panel is not voided, the use of Siemens breakers is required.
7. Square D by Schneider Electric HOM4080M200PQCVP Homeline 200 Amp 40-Space 80-Circuit Indoor Main Breaker Qwik-Grip Plug-On Neutral Load Center with Cover – Value Pack
Innovative cable entry system quickly grips the branch wires while eliminating steel ko’s and cable Connectors for a faster installation
Includes a fully distributed Neutral bar, allowing for the installation of Homeline plug-on Neutral combination arc fault breakers on any space
Each pole space accepts full-size, tandem or quad breakers
Voltage: 120/240 V AC
Ground and Neutral bars accept up to (3) #10-14 equipment Grounds flush/surface indoor cover
Includes (3) HOM120 Homeline 20 amp single-pole circuit breakers, (2) HOM230 Homeline 30 amp double-pole circuit breakers and a combination
Description
Product Description
The Square D by Schneider Electric Homeline value pack 200 amp 40-Space 80-circuit indoor convertible main breaker qwik-grip load center for Plug-on neutral breakers includes a cover and a selection of breakers. It is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings.
From the Manufacturer
WARNING: This product can expose you to chemicals including Lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Siemens 200 Amp circuit breaker enclosure includes an outdoor rated enclosure and a QN2200H, 200 Amp, circuit breaker. This panel is ideal as a disconnecting means for a house, building, or piece of equipment.
9. Square D by Schneider Electric RC816F200C Homeline 200-Amp Main Breaker 8-Space 16-Circuit Outdoor Overhead/Underground CSED
Homelline 200 Amp 8-Space 16-Circuit Ringless Overhead/Underground Service Main Breaker CSED
Accommodates plug-on secondary surge arrestor and features a plug-in design for easy installation
Use type HOM circuit breakers, Rated 120/240Vac,
4 jaw meter socket
NEMA type 3R enclosure
Description
Product Description
The Square D 200 Amp 8-Space 16-Circuit Combination Meter Socket and Main Breaker Load Center is suitable for use as a combination service entrance device (CSED). This unit is ANSI certified and UL listed with a maximum 22,000 AIR. The ringless unit is intended for use as a combination meter socket and main breaker load center. It is suitable for overhead or underground service applications. The unit has feed-through lugs. This CSED is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline CSEDs are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline CSEDs are engineered for fast installation and wire savings.
From the Manufacturer
WARNING: This product can expose you to chemicals including Lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
10. Square D by Schneider Electric HOM2040M200PCVP Homeline 200-Amp 20-Space 40-Circuit Indoor Main Breaker Load Center Value Pack, Plug-on Neutral Ready
Square D by Schneider Electric Homeline, 200A, Plug On Neutral, Main Breaker Installed Indoor Load Center Value Pack, 20 Space Circuit, 40 Single Poles & 3 Each Hom120 20A Single Pole & 2 Each Hom230 30A 2 Pole Circuit Breakers Included.
From the Manufacturer
WARNING: This product can expose you to chemicals including Lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Conclusion
By our suggestions above, we hope that you can found Ge Outside Circuit Breaker Box for you.Please don’t forget to share your experience by comment in this post. Thank you!
For Use With Siemens Q Series (Qp Series) Circuit Breakers 3 Wire 120/240VacAluminum Bus Made in: United States Dimensions: 1 X 1 X 1Brand: Siemens Item Weight: 3.6includes: Unit Instruction Guide
From the Manufacturer
Siemens circuit breaker enclosure is rated at 60 Amps max and will accept a variety of breaker options. Two single pole breakers, one double pole breaker, or four 1/2-inch frame breakers with a total Amperage of 60 Amps. The enclosure is outdoor rated. Breaker not included.
4. GE RV Outlet Box 70 Amp 120/240 Volt Unmetered with 50 Amp and 20 Amp GCFI Circuit Protected Receptacles
Rugged 16-gauge zinc coated G-90 steel, with electro-deposition finish resists corrosion and fading
NEMA 3R rainproof enclosure protects against weather, vandalism and nuisance tripping
Factory wired, assembled and tested
All-in-1 construction for factory assured terminations
Description
Unmetered RV outlet box. Rugged 16-gauge zinc coated G-90 steel, with electro-deposition finish resists corrosion and fading. NEMA 3R rainproof enclosure protects against weather, vandalism and nuisance tripping. Factory wired, assembled and tested. All-in-1 construction for factory assured terminations. Suitable for use as service entrance equipment when installed in accordance with the National Electric Code. Accepts copper or aluminum wire for added installation flexibility. Rolled edge door for cord protection. Dead front construction prevents accidental contact with live parts. Stay open position on door for convenience. Padlock provision. UL/CUL Listed (Power Outlets).
5. Square D by Schneider Electric RC816F200C Homeline 200-Amp Main Breaker 8-Space 16-Circuit Outdoor Overhead/Underground CSED
Homelline 200 Amp 8-Space 16-Circuit Ringless Overhead/Underground Service Main Breaker CSED
Accommodates plug-on secondary surge arrestor and features a plug-in design for easy installation
Use type HOM circuit breakers, Rated 120/240Vac,
4 jaw meter socket
NEMA type 3R enclosure
Description
Product Description
The Square D 200 Amp 8-Space 16-Circuit Combination Meter Socket and Main Breaker Load Center is suitable for use as a combination service entrance device (CSED). This unit is ANSI certified and UL listed with a maximum 22,000 AIR. The ringless unit is intended for use as a combination meter socket and main breaker load center. It is suitable for overhead or underground service applications. The unit has feed-through lugs. This CSED is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline CSEDs are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline CSEDs are engineered for fast installation and wire savings.
From the Manufacturer
WARNING: This product can expose you to chemicals including Lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
6. Square D by Schneider Electric QO Plug-On Neutral 100 Amp Main Breaker 24-Space 24-Circuit Indoor Load Center with Cover
Overhead/underground feed simply by rotating the device before installing
Single phase
Rated 120/240 VAC and 22,000 AIR short circuit current rating
Description
Size:Pack
Product Description
Square D by Schneider Electric QO, 100A Main Breaker Installed Load Center, Plug On Neutral, Combination Cover For Flush Or Surface Mount, 24 Space Circuit 24 Single Poles.
From the Manufacturer
WARNING: This product can expose you to chemicals including Lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 8 spaces and 16 circuits maximum 1-pole, 4 QP breakers maximum 2-pole, 120/240 volt. 10,000 AIR. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service entrance equipment when a main breaker (125 amp maximum) is back-fed in branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. 12-3/8″ x 14-3/4″ x 3-7/8″. UL Listed, complies fully with NEC and UL requirements for Class CTL.
From the Manufacturer
Siemens 8 space, 16 circuit, Main Lug Load Center is 125 Amp rated and intended for Surface mount applications. This enclosure is indoor rated.
8. Square D by Schneider Electric HOM3060M100PC Homeline 100 Amp 30-Space 60-Circuit Indoor Main Breaker Load Center with Cover (Plug-on Neutral Ready),
The Square D Homeline 100 Amp 30-Space 60-Circuit Indoor Convertible Main Breaker Load Center with cover for Plug-on Neutral breakers is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings.
From the Manufacturer
WARNING: This product can expose you to chemicals including Lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
9. Square D by Schneider Electric QO612L100DS QO 100-Amp 6-Space 12-Circuit Indoor Main Lugs Load Center with Surface Mount Cover, Gray
Main feeders terminate from the top, feeders can enter from any direction, however, device cannot be rotated
Single phase
Rated 120/240 VAC and 10,000 AIR short circuit current rating
Description
Product Description
The Square D QO 100 Amp 6-Space 12-Circuit Fixed Main Lugs Indoor Load Center is UL listed for residential, commercial and industrial power distribution. This load center is built with a rugged themoplastic interior and an aluminum bus bar plated for reliability. QO load centers are tested and listed only for QO circuit breakers. QO load centers are the “World’s Finest” designed with industry leading features for flexible application. QO load centers include features engineered for fast installation and wire savings.
From the Manufacturer
WARNING: This product can expose you to chemicals including Lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
10. Square D by Schneider Electric QO2100NRBCP QO 100 Amp Two-Pole Outdoor Circuit Breaker Enclosure with QO2100 Breaker Included
Square D by Schneider Electric QO2100NRBCP 100A QO Rainproof Enclosure With Breaker & Door, 120/240V.
From the Manufacturer
WARNING: This product can expose you to chemicals including Lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Conclusion